CatalogueFire Hydrant WorkFire Pump Skids & Manifolds

Images are representative illustrations. Products are custom-engineered to your requirement and actual appearance may vary.

Fire Pump Skids & Manifolds

We engineer and supply Fire Pump Skids & Manifolds as part of complete industrial heating and utility solutions. Share your capacity, fuel type, application, and site details — our team will recommend a suitable configuration and quote.

Pump Flow Capacity
Sized to fire water demand
Custom capacities available on request
Head / Pressure
Sized to system head requirementAs per IS 12469 / NBC / TAC

About Fire Pump Skids & Manifolds

Gyantosh designs and fabricates Fire Pump Skids & Manifolds — the pressurised heart of a fire protection system. A fire pump skid packages the main fire pump, standby (diesel) pump, and jockey (pressure-maintenance) pump together with their suction and discharge manifolds, valves, and instrumentation on a single, factory-assembled, tested base, ready for rapid site installation.

Skid-mounting delivers a matched, pre-piped, pre-wired set that eliminates site integration risk and speeds commissioning. GyanTosh configures pump sets to the required flow and head as per IS 12469 / NBC / TAC, with electric-motor-driven main and jockey pumps and a diesel-engine-driven standby pump that ensures fire water is available even during a power failure.

The discharge manifold, isolation and non-return valves, pressure switches, air vessel, and control panel are all integrated and tested on the skid. Robust fabrication, quality pumps, and corrosion protection ensure dependable operation over a long service life.

GyanTosh supplies fire pump skids and manifolds standalone or within complete fire hydrant, sprinkler, and foam system projects, backed by over two decades of engineering and fabrication experience.

Fire Pump Skids & Manifolds Key Features

  • Factory-assembled, pre-piped, pre-wired, and tested skid
  • Main, standby (diesel), and jockey pump configuration
  • Diesel standby pump for firefighting during power failure
  • Integrated suction and discharge manifolds
  • Isolation, non-return, and control valves
  • Air vessel and pressure-switch control
  • Configured to IS 12469 / NBC / TAC
  • Sized to required fire water flow and head
  • Control panel and instrumentation included
  • Rapid site installation and commissioning
  • Robust fabrication with corrosion protection
  • Integrates with hydrant, sprinkler, and foam systems

Fire Pump Skids & Manifolds Specification

Scope
Fire pump skid with manifolds
Pump Set
Main (electric) + Standby (diesel) + Jockey
Flow Capacity
Sized to fire water demand
Head / Pressure
Sized to system head requirement
Standards
IS 12469 / NBC / TAC
Assembly
Factory-assembled, pre-piped & tested skid
Controls
Panel, air vessel & pressure switches integrated

Pump Set Configuration

Main Fire Pump

An electric-motor-driven main pump delivers the full design fire water flow and head during a fire event.

Diesel Standby Pump

A diesel-engine-driven standby pump automatically ensures fire water availability even during a mains power failure.

Jockey Pump

A small jockey pump maintains system pressure and makes up minor leakage, preventing the main pumps from cycling on small demands.

Integrated Manifold & Controls

Suction/discharge manifolds, valves, air vessel, pressure switches, and control panel are assembled and tested together on the skid.

Fire Pump Skids & Manifolds Applications

Fire Hydrant System PressurisationSprinkler System SupplyFoam System SupplyFire Monitor SupplyPlant Fire ProtectionBuilding & Warehouse Fire Systems

Industries Served

Chemical IndustriesPharmaceutical PlantsPower PlantsWarehousing & LogisticsManufacturing FacilitiesPetrochemical & RefineriesProcess Industries

Advantages of a Fire Pump Skids & Manifolds

Rapid, Low-Risk Installation

Factory-assembled and tested skids eliminate site integration risk and dramatically speed installation and commissioning.

Guaranteed Availability

The diesel standby pump ensures fire water is available even during a power failure — when fires are often most likely.

Stable System Pressure

The jockey pump maintains system pressure and prevents unnecessary cycling of the main pumps on small leaks.

Code Compliant

Pump sets configured to IS 12469 / NBC / TAC support statutory and insurance approval.

Matched & Tested

Pumps, manifolds, valves, and controls are supplied as one matched, pre-tested package for reliable operation.

Durable Construction

Robust fabrication, quality pumps, and corrosion protection deliver long, dependable service life.

Optional Accessories

Main Fire Pump (Electric)
Standby Fire Pump (Diesel)
Jockey Pump
Suction & Discharge Manifolds
Isolation & Non-Return Valves
Air Vessel
Pressure Switches
Control Panel & Instrumentation

Frequently Asked Questions(6)

What is a fire pump skid?
A fire pump skid packages the main, standby (diesel), and jockey pumps with their suction/discharge manifolds, valves, air vessel, and control panel on a single factory-assembled, pre-tested base — ready for rapid site installation.
Why is a diesel standby pump needed?
The diesel-engine-driven standby pump ensures fire water remains available even during a mains power failure — a critical requirement, since power may be lost during a fire.
What does the jockey pump do?
The jockey pump maintains system pressure and makes up minor leakage, so the large main pumps do not start and stop repeatedly for small pressure drops.
How is the pump set sized?
The pumps are sized to the required fire water flow and head as per IS 12469, NBC, and TAC requirements for the specific facility.
Why choose a skid over site-assembled pumps?
A factory-assembled and tested skid eliminates site integration risk, ensures the components are properly matched, and dramatically speeds installation and commissioning.
Can the skid feed hydrant, sprinkler, and foam systems?
Yes. The fire pump skid pressurises the fire water network that supplies hydrants, sprinklers, monitors, and foam systems.
What we’ll need for a fast quote
  • Capacity / size requirements
  • Process or application details
  • Material preference (M.S / S.S where applicable)
  • Installation location & delivery timeline
Quick Inquiry
GYANTOSH FABRICATORS PRIVATE LIMITED

Share your capacity, fuel type, and application — we respond within 24 hours.

4, Nyay Nagar, Indore, Madhya Pradesh 452010, India