Module 07 · Steam Mains4 min read

Draining Steam Mains: Drip Legs, Traps and Warm-up Load

Every steam main makes condensate: from heat loss in service, and in a flood when it is warmed from cold. That water has to be drained at the right points, through pockets big enough to catch it, or the steam picks it up and throws it at the next bend.

ByShikhar Singh·Steam Consultant & IT Consultant·Published

You'll learn

  • Explain where condensate in a main comes from
  • Place drain points and size drip legs
  • Calculate warm-up and running condensate loads
  • Understand why warm-up load decides drainage

Before this: Sizing steam pipes, Latent heat

BeginnerThe idea in plain words, and where you meet it. No maths.

Where the water comes from

A steam main is hotter than the air around it, so it loses heat all the time, even when insulated. The steam inside gives up its latent heat to replace that loss, and condenses. On a cold start, far more condenses: the whole mass of steel has to be heated from ambient to steam temperature, and every kilojoule of that comes from condensing steam.

Water lying in a main is dangerous. Steam travelling at 30 m/s can pick up a slug of water and drive it into a bend or a valve like a hammer blow. The fix is to collect the water at low points and drain it away through steam traps before it can accumulate.

IntermediateThe formula, its units, and a worked example on real plant numbers.

Drain points and drip legs

  • Slope mains down in the direction of flow, so condensate runs with the steam to the drain points.
  • Drain at every low point, before risers, before control valves and at the end of every main.
  • On long straight runs, drain at regular intervals — commonly every 30–50 m.
  • Use a drip leg (pocket) of generous diameter: a small hole in the bottom of the pipe lets most of the water rush past.
  • Take the trap connection from the side of the pocket, a little above its bottom, so dirt settles below it.

Pocket size follows the main. GyanTosh’s pipe code follows EN 45510-1: On mains from DN125 to DN200 the pocket should be DN100 and at least 150 mm deep.

ExpertThe fine print: where the simple model breaks, and what it costs.

Warm-up load decides the drains

Worked example
150 m of DN80 at 10 kg/cm²(g)
Given
  • Warmed from 30 °C to steam temperature (183 °C) in 20 minutes; insulated with 50 mm in service.
  1. Steel to heat: about 1,863 kg including fittings. Warm-up condensate: 210 kg/h during the 20 minutes.
  2. Running condensate once warm, insulated: 22.0 kg/h. Bare, it would be about 240 kg/h.
Answer: The start-up load is about 10 times the running load.

Drain traps sized on the running load — the figure on the heat balance — cannot clear the start-up flood. Water collects, the steam picks it up, and the main hammers every morning; the traps get blamed. Size main drains for the warm-up load at the warm-up time the plant actually uses, or warm the main more slowly with the drains open.

Key takeaways

  • Mains make condensate from heat loss in service and, far more, during warm-up.
  • Slope with the flow, drain every low point and riser and every 30–50 m, with full-size drip legs.
  • Warm-up load on 150 m of DN80 is about 10 times the running load.
  • Size main drains for warm-up, not running load.

Check your understanding

Questions run from beginner to expert. Try each before opening the answer.

  1. Beginner

    Q1. Why must condensate be drained from steam mains?

    1. A.It wastes water
    2. B.Steam can drive slugs of it into bends and valves, causing water hammer
    3. C.It cools the boiler
    4. D.It is a legal rule
    Show answer

    B. Accumulated water becomes a projectile at steam velocities.

  2. Intermediate

    Q2. Which way should a steam main slope?

    1. A.Up in the direction of flow
    2. B.Down in the direction of flow
    3. C.Level
    4. D.It does not matter
    Show answer

    B. Condensate then runs with the steam to the drain points.

  3. Intermediate

    Q3. Why should the drip pocket be close to the main’s diameter?

    1. A.Looks
    2. B.A small hole lets most water rush past
    3. C.To hold more steam
    4. D.For strength
    Show answer

    B. A large pocket catches the water moving along the bottom of the pipe.

  4. Expert

    Q4. Which load should main drain traps be sized for?

    1. A.Running load only
    2. B.Warm-up load
    3. C.Half the running load
    4. D.Boiler output
    Show answer

    B. Warm-up produces many times the running condensate.

Frequently asked

Where should steam main drains be located?
At every low point, before risers and control valves, at the end of each main, and at regular intervals — commonly every 30–50 m — on long runs, using drip legs of generous diameter.
What is warm-up load in a steam main?
The condensate formed while heating the pipe metal from cold to steam temperature. It is many times the running load and should decide the size of the main drains.

Training a boiler team?

These lessons follow the order we train operators in. We also run on-site operator and maintenance training, built around your own plant.

Boiler operator training →