Module 01 · Heat and Energy9 min read

Latent Heat of Steam: What It Is and Why It Falls as Pressure Rises

Latent heat is the heat that changes water into steam without changing its temperature, and the heat steam gives back when it condenses. It is why industry heats with steam, and it is not a fixed number: the higher the pressure, the less of it each kilogram of steam carries.

ByShikhar Singh·Steam Consultant & IT Consultant·Published

You'll learn

  • Define latent heat and the enthalpy of evaporation hfg
  • Read how hf, hfg and hg change with pressure
  • Calculate the steam flow a heating load needs
  • Avoid the 540 kcal/kg shortcut and the error it brings

Before this: Sensible heat

BeginnerThe idea in plain words, and where you meet it. No maths.

What latent heat is

Heat water at atmospheric pressure and its temperature climbs to 100 °C, then stops. The burner is still firing and heat is still going in, but the thermometer does not move until the last of the water has turned to steam. That heat has not disappeared; it has gone into pulling the water molecules apart into a vapor. Because a thermometer cannot see it, it is called latent, meaning hidden, heat.

The same heat comes back out when steam condenses, again at constant temperature. That return is the entire point of a steam system: the boiler loads heat into the steam as latent heat, the pipes carry it, and the process takes it out by condensing the steam against a cooler surface.

Why industry heats with steam

Latent heat is large. One kilogram of steam condensing at 4 kg/cm²(g) releases 2,109 kJ. To deliver the same heat from hot water cooling by 20 °C, you would need to circulate about 25 kg of water. That is why steam lines are small for the heat they carry, and why hot water and thermic fluid systems need pumps and larger pipework.

It is also released at a fixed temperature. Steam at 4 kg/cm²(g) condenses at 151.4 °C and nowhere else, so a process held at a steady pressure is held at a steady temperature. Controlling temperature with a pressure reducing valve and a gauge is a direct consequence of latent heat.

IntermediateThe formula, its units, and a worked example on real plant numbers.

The formulas

In steam tables, latent heat is the enthalpy of evaporation, written hfg: the difference between saturated steam, hg, and saturated water at the same pressure, hf.

Heat released by condensing steam
Q=mhfg
Symbols in the formula
SymbolMeaningUnit
QHeat releasedkJ
mMass of steam condensedkg
hfgLatent heat (enthalpy of evaporation) at the steam pressurekJ/kg
Total heat of dry saturated steam
hg=hf+hfg
Symbols in the formula
SymbolMeaningUnit
hgEnthalpy of dry saturated steamkJ/kg
hfEnthalpy of saturated water: the sensible heat to reach boiling pointkJ/kg
hfgLatent heat to turn that water into steamkJ/kg

All three are measured from water at 0.01 °C, the reference point of the steam tables, which is why they can be added and subtracted directly.

Worked example: steam flow for a heating load

Worked example
Steam needed by a 500 kW process heater
Given
  • A heat exchanger needs 500 kW: 500 kJ every second.
  • Dry saturated steam is available at 4 kg/cm²(g), and condensate leaves at saturation temperature, so only latent heat is used.
  1. Latent heat at 4 kg/cm²(g), from a steam table: 2,109.4 kJ/kg.
  2. Rearrange Q=mhfg for the steam flow, converting seconds to hours:
    m=500×36002,109.4=853 kg/h
  3. The same load supplied at 10 kg/cm²(g), where hfg is 2,002.1 kJ/kg, needs 899 kg/h: more steam, because each kilogram carries less latent heat.
Answer: 853 kg/h at 4 kg/cm²(g). This is why steam is distributed at high pressure, where its volume is small and pipes can be too, and reduced to the lowest pressure the process allows at the point of use.

Two assumptions are hiding in that answer. The steam must be dry: steam that is 95% dry carries only 95% of its latent heat, so the flow rises accordingly. And the condensate must be removed as it forms, by a steam trap; condensate left in the exchanger blankets the surface and the latent heat never gets out.

ExpertThe fine print: where the simple model breaks, and what it costs.

Latent heat falls as pressure rises

Saturated steam properties by gauge pressure
Pressure, kg/cm²(g)Saturation temp., °Chf, kJ/kghfg, kJ/kghg, kJ/kghfg, kcal/kg
0100.0419.02,256.52,675.5539.0
2133.2560.22,164.32,724.5516.9
4151.4638.12,109.42,747.5503.8
7169.8718.22,049.42,767.7489.5
10183.3778.02,002.12,780.1478.2
17.5207.6886.81,909.42,796.2456.1
21216.3926.71,873.22,799.9447.4
40250.71,089.21,711.62,800.8408.8

Computed from IAPWS-IF97 with atmospheric pressure at 1.0332 kg/cm². Gauge 0 is atmospheric.

Stacked chart of the enthalpy of saturated steam from 0 to 40 kg/cm²(g). The total, hg, stays between 2,676 and about 2,800 kJ/kg, while the latent part, hfg, falls from 2,257 to 1,712 kJ/kg and the sensible part, hf, grows.
The total heat in steam barely changes with pressure. What changes is the split: more sensible, less latent. Chart: GyanTosh Fabricators Pvt. Ltd., reusable with credit under CC BY 4.0

From atmospheric pressure to 10 kg/cm²(g), the total heat in a kilogram of steam rises only from 2,676 to 2,780 kJ/kg. But the latent part falls from 2,257 to 2,002 kJ/kg, because more of the total is now sensible heat in water that boils at 183 °C instead of 100 °C. Keep raising the pressure and latent heat keeps shrinking, reaching zero at the critical point, about 224 kg/cm²(g), where water and steam stop being distinguishable. That is why a supercritical power boiler has no drum: there is no boiling to separate.

Latent heat as a rating datum: F&A 100 °C

Indian boilers are rated “from and at 100 °C”: the steam the boiler would make from water at 100 °C into steam at 100 °C. That is pure latent heat at atmospheric pressure, taken by convention as 2,256.9 kJ/kg, and it makes boilers comparable whatever pressure and feedwater temperature they will actually run at.

A boiler’s real output is lower, because at working pressure each kilogram of steam needs the latent heat plus the sensible heat to bring cold feedwater up to boiling point. The ratio between the two is the evaporation factor, which comes up again in Module 02, Boiler Fundamentals; the F&A 100 °C converter works it out for a given pressure and feedwater temperature.

Key takeaways

  • Latent heat changes state at constant temperature. For steam it is hfg, and hg=hf+hfg.
  • It falls as pressure rises: 2,257 kJ/kg at atmospheric pressure, 2,002 at 10 kg/cm²(g).
  • Size steam supplies with hfg at the pressure of use, never the 539 kcal/kg atmospheric figure.
  • Distribute steam at high pressure, use it at the lowest pressure the process allows.

Check your understanding

Questions run from beginner to expert. Try each before opening the answer.

  1. Beginner

    Q1. What happens to the temperature of boiling water while latent heat is being added?

    1. A.It rises steadily
    2. B.It stays constant
    3. C.It falls
    4. D.It rises, then falls
    Show answer

    B. Latent heat changes state, not temperature. The water stays at its saturation temperature until it has all boiled.

  2. Beginner

    Q2. Why can a steam pipe carry far more heat than a hot water pipe of the same size?

    1. A.Steam is hotter than any hot water
    2. B.Each kilogram of steam gives up a large amount of latent heat when it condenses
    3. C.Steam flows more slowly
    4. D.Steam pipes are always insulated
    Show answer

    B. Condensing releases about 2,109 kJ per kilogram at 4 kg/cm²(g); water cooling by 20 °C gives up only about 84.

  3. Intermediate

    Q3. A process needs 586 kW. Roughly how much dry saturated steam at 4 kg/cm²(g) is that?

    1. A.100 kg/h
    2. B.1,000 kg/h
    3. C.10,000 kg/h
    4. D.2,109 kg/h
    Show answer

    B. 586 kW is 21,09,445 kJ/h, and each kilogram condensing gives 2,109 kJ, so 1,000 kg/h.

  4. Intermediate

    Q4. Why is steam usually distributed at a higher pressure than the process uses?

    1. A.Higher-pressure steam carries more latent heat per kilogram
    2. B.Higher-pressure steam is denser, so smaller pipes carry it
    3. C.Steam traps only work at high pressure
    4. D.Low-pressure steam cannot be metered
    Show answer

    B. Pressure shrinks the volume. The latent heat per kilogram is actually lower at high pressure, which is why the pressure is reduced again at the point of use.

  5. Expert

    Q5. As steam pressure rises from 0 to 10 kg/cm²(g), what happens to hfg and hg?

    1. A.Both rise
    2. B.hfg falls; hg barely changes
    3. C.hfg rises; hg falls
    4. D.Both stay the same
    Show answer

    B. hfg falls from 2,257 to 2,002 kJ/kg while hg moves only from 2,676 to 2,780.

  6. Expert

    Q6. At about what pressure does the latent heat of water fall to zero?

    1. A.100 kg/cm²(g)
    2. B.About 224 kg/cm²(g), the critical point
    3. C.It never reaches zero
    4. D.540 kg/cm²(g)
    Show answer

    B. At the critical point, 22.064 MPa absolute, liquid and vapor become indistinguishable and there is no boiling, so no latent heat.

Frequently asked

What is the latent heat of steam?
It is the heat needed to turn water at its boiling point into steam at the same temperature, and the heat released when that steam condenses. At atmospheric pressure it is 2,256.5 kJ/kg (about 539 kcal/kg); at 10 kg/cm²(g) it is 2,002.1 kJ/kg.
Why does latent heat decrease as pressure increases?
At higher pressure water boils at a higher temperature, so more of the total heat in steam is already sensible heat in the water. The total heat of steam stays nearly constant, so the latent part shrinks, reaching zero at the critical point.
What is the formula for latent heat?
Q = m × hfg, where hfg is the enthalpy of evaporation at the steam pressure. The total heat of dry saturated steam is hg = hf + hfg.
What is the latent heat of steam in kcal/kg?
About 539 kcal/kg at atmospheric pressure, falling to 503.8 kcal/kg at 4 kg/cm²(g) and 478.2 kcal/kg at 10 kg/cm²(g).

Related equipment

Training a boiler team?

These lessons follow the order we train operators in. We also run on-site operator and maintenance training, built around your own plant.

Boiler operator training →

Sources

About the author

Shikhar SinghSteam Consultant & IT Consultant

Shikhar Singh is a Steam Consultant and IT Consultant at GyanTosh Fabricators Pvt. Ltd., where he works on steam system sizing, condensate recovery and the engineering content published on this site.

Full profile and background →