Module 09 · Heat Transfer3 min read

The Heat Exchanger Equation: U-value, LMTD and Fouling

Every heat exchanger, from a boiler economizer to a process heater, follows one equation: heat transferred equals an overall coefficient, times area, times a mean temperature difference. Knowing how each term behaves explains how exchangers are sized and why they lose output as they foul.

ByShikhar Singh·Steam Consultant & IT Consultant·Published

You'll learn

  • Use Q = U A LMTD
  • Calculate a log mean temperature difference
  • Understand what the overall U-value includes
  • Allow for fouling

Before this: Conduction, convection and radiation, Sensible heat

BeginnerThe idea in plain words, and where you meet it. No maths.

Three things decide how much heat moves

  • How easily heat crosses the wall between the fluids — the overall coefficient, U.
  • How much wall there is — the area, A.
  • How big the temperature difference is between the two fluids — the driving force.

Double any one of them and, other things equal, the heat transferred doubles. A dirty exchanger loses U; a small one lacks A; one fed with steam at too low a pressure lacks temperature difference.

IntermediateThe formula, its units, and a worked example on real plant numbers.

Q = U A LMTD

Heat exchanger equation
Q=UAΔTlm
Log mean temperature difference
ΔTlm=ΔT1−ΔT2ln⁡(ΔT1/ΔT2)
Symbols in the formula
SymbolMeaningUnit
ΔT1, ΔT2Temperature differences between the fluids at the two endsK
Worked example
A steam water heater
Given
  • 5,000 kg/h of water heated from 30 to 80 °C by steam at 4 kg/cm²(g) (151.4 °C).
  • Overall U assumed at 1,500 W/(m²·K) for illustration.
  1. End differences: 121.4 K and 71.4 K.
  2. LMTD:
    121.4−71.4ln⁡(121.4/71.4)=94.1 K
  3. Heat duty: 290 kW.
  4. Area:
    A=2,90,4341,500×94.1=2.1 m2
Answer: About 2.1 m² of heating surface, before any allowance for fouling.
ExpertThe fine print: where the simple model breaks, and what it costs.

What U contains, and fouling

Overall coefficient, resistances in series
1U=1h1+tk+1h2+Rf
Symbols in the formula
SymbolMeaningUnit
h1, h2Film coefficients on each sideW/(m²·K)
t/kWall resistancem²·K/W
RfFouling resistance allowancem²·K/W

Fouling — scale, sludge, product deposits, soot — adds resistance over time. Designers add a fouling allowance so that the exchanger still meets duty when dirty. Adding 0.0002 m²·K/W to the example drops U from 1,500 to 1,154 and raises the required area from 2.1 to 2.7 m².

Arithmetic mean temperature difference overstates the driving force whenever the end differences are very unequal; LMTD is the correct mean for exchangers with one side at constant temperature, as condensing steam is. For other flow arrangements, a correction factor is applied to the counterflow LMTD.

Key takeaways

  • Q = U × A × LMTD.
  • LMTD = (ΔT₁ − ΔT₂) / ln(ΔT₁/ΔT₂).
  • 1/U is the sum of the film, wall and fouling resistances.
  • Fouling allowances add area; cleaning restores U.

Check your understanding

Questions run from beginner to expert. Try each before opening the answer.

  1. Beginner

    Q1. Which change does NOT increase heat transferred?

    1. A.More area
    2. B.Higher U
    3. C.Larger temperature difference
    4. D.More fouling
    Show answer

    D. Fouling adds resistance and reduces U.

  2. Intermediate

    Q2. End differences are 100 K and 50 K. LMTD?

    1. A.75 K
    2. B.About 72 K
    3. C.50 K
    4. D.150 K
    Show answer

    B. (100 − 50) / ln 2 ≈ 72.1 K.

  3. Intermediate

    Q3. Q = 100 kW, U = 1,000 W/(m²·K), LMTD = 50 K. Area?

    1. A.0.5 m²
    2. B.2 m²
    3. C.20 m²
    4. D.5 m²
    Show answer

    B. 100,000 / (1,000 × 50) = 2 m².

  4. Expert

    Q4. What does a fouling allowance do in design?

    1. A.Lowers cost
    2. B.Adds resistance so the exchanger still meets duty when dirty
    3. C.Removes scale
    4. D.Raises U
    Show answer

    B. It sizes in extra area.

Frequently asked

What is LMTD in a heat exchanger?
The log mean temperature difference: (ΔT₁ − ΔT₂) ÷ ln(ΔT₁/ΔT₂), using the temperature differences between the fluids at each end. It is the correct average driving force for Q = U·A·LMTD.
What is a fouling factor?
An allowance for the extra resistance of deposits that build up in service, added to 1/U in design so the exchanger still meets its duty when dirty.

Training a boiler team?

These lessons follow the order we train operators in. We also run on-site operator and maintenance training, built around your own plant.

Boiler operator training →

Sources

About the author

Shikhar SinghSteam Consultant & IT Consultant

Shikhar Singh is a Steam Consultant and IT Consultant at GyanTosh Fabricators Pvt. Ltd., where he works on steam system sizing, condensate recovery and the engineering content published on this site.

Full profile and background →