Module 11 · Emissions and Environment5 min read

Particulate Control and Stack Height for Industrial Boilers

Solid-fuel boilers make dust, and the collector between boiler and chimney decides whether the stack meets its limit. The chimney itself then disperses what remains, and its minimum height is set by formula.

ByShikhar Singh·Steam Consultant & IT Consultant·Published

You'll learn

  • Describe how each type of dust collector works
  • Choose a collector for a fuel and a limit
  • Apply the CPCB stack height formulas
  • Recognize common collector failures

Before this: Stack Emission Norms and Consent

BeginnerThe idea in plain words, and where you meet it. No maths.

Where the dust comes from and where it goes

Coal and biomass contain ash. Some falls through the grate or drains from the bed as bottom ash; the rest leaves the furnace with the flue gas as fly ash. Between the boiler and the chimney, a collector removes as much of it as it can, and the ID fan draws the cleaned gas up the stack.

  • Cyclone: gas spins, and dust is thrown to the wall and falls out. Simple, no moving parts, good on coarse dust.
  • Multicyclone: many small cyclones in parallel. Smaller diameter spins harder and catches finer dust.
  • Bag filter: gas passes through fabric bags; dust builds up on them and is pulsed off with compressed air. Catches fine dust very well.
  • Electrostatic precipitator (ESP): dust is charged and drawn to collecting plates. Very low pressure drop at large gas volumes.
  • Wet scrubber: dust is caught in water sprays. Also absorbs some acid gases, but makes a wet effluent to treat.
IntermediateThe formula, its units, and a worked example on real plant numbers.

Choosing a collector

Collector choice in practice
CollectorTypical roleWatch out for
Cyclone / multicyclonePre-cleaner, or alone on small boilers with a lenient limitFine dust passes straight through
Bag filterMeeting tight limits on biomass and coalSparks and hot gas burn bags; acid dew point blinds them
ESPLarger boilers, large gas volumesPerformance depends on dust resistivity and gas conditions
Wet scrubberWhere gas is also sticky or acidicWater treatment, corrosion, a wet plume

With today’s limits of 150 and 100 mg/Nm³ for most fuels above 2 TPH, a cyclone alone rarely meets the standard; a multicyclone ahead of a bag filter or ESP is the usual answer, with the multicyclone taking the coarse load and sparks off the fine collector.

ExpertThe fine print: where the simple model breaks, and what it costs.

Stack height

CPCB guidelines set a minimum stack height from the emission rate, so that what leaves disperses before it reaches the ground. Two formulas apply; the stack must meet the greater of them and the minimum for the boiler’s size.

Stack height from SO₂ emission
H=14Q0.3
Symbols in the formula
SymbolMeaningUnit
HStack height above groundm
QSO₂ emission ratekg/h
Stack height from particulate emission
H=74Q0.27
Symbols in the formula
SymbolMeaningUnit
HStack height above groundm
QParticulate emission ratet/h

The minimum is 11 m for boilers below 2 TPH and 30 m for larger ones.

Worked example
Stack height for a 5 TPH coal-fired boiler
Given
  • 5,000 kg/h of steam at 10.54 kg/cm²(g), feedwater 80 °C; coal at 4,000 kcal/kg GCV, 82% efficiency; 0.5% sulfur, illustrative.
  1. Coal burnt: 5,000 × (2,781.8 − 335.8) ÷ (0.82 × 4,000 × 4.1868) = 891 kg/h.
  2. SO₂: every kilogram of sulfur becomes two of SO₂, so 891 × 0.005 × 2 = 8.9 kg/h.
  3. Height from SO₂:
    H=14×8.90.3=27.0 m
  4. Minimum for a boiler of 2 TPH and above: 30 m.
Answer: The stack must be at least 30 m, unless the particulate formula or the consent asks for more.

Key takeaways

  • Collectors: cyclone and multicyclone for coarse dust; bag filter and ESP for fine; scrubber for sticky or acidic gas.
  • Above 2 TPH, meeting 150 or 100 mg/Nm³ usually takes a multicyclone plus a bag filter or ESP.
  • H=14Q0.3 (SO₂, kg/h) and H=74Q0.27 (PM, t/h); take the larger, with a minimum of 11 m or 30 m.
  • Protect bag filters from sparks and from running below the acid dew point.

Check your understanding

Questions run from beginner to expert. Try each before opening the answer.

  1. Beginner

    Q1. Which collector uses fabric to catch dust?

    1. A.Cyclone
    2. B.Bag filter
    3. C.ESP
    4. D.Scrubber
    Show answer

    B. Dust builds up on the bags and is pulsed off.

  2. Intermediate

    Q2. Why put a multicyclone ahead of a bag filter?

    1. A.To heat the gas
    2. B.To take the coarse dust and sparks off the bags
    3. C.It is required by law
    4. D.To add draft
    Show answer

    B. It protects and unloads the fine collector.

  3. Intermediate

    Q3. What is the minimum stack height for a 5 TPH boiler?

    1. A.11 m
    2. B.30 m
    3. C.50 m
    4. D.No minimum
    Show answer

    B. 30 m for boilers of 2 TPH and above.

  4. Expert

    Q4. If the SO₂ formula gives 28 m and the PM formula 33 m, the stack must be:

    1. A.28 m
    2. B.30 m
    3. C.33 m
    4. D.The average
    Show answer

    C. The greatest of the two formulas and the minimum.

Frequently asked

How is boiler chimney height calculated in India?
Under CPCB guidelines, as the greater of H = 14 Q^0.3, with Q the SO₂ emission in kg/h, and H = 74 Q^0.27, with Q the particulate emission in t/h, subject to a minimum of 11 m below 2 TPH and 30 m above. The consent may set a different height.
Which dust collector is best for a biomass boiler?
Usually a multicyclone followed by a bag filter or ESP. The multicyclone removes coarse ash and sparks; the bag filter or ESP removes the fine dust needed to meet current limits.

Training a boiler team?

These lessons follow the order we train operators in. We also run on-site operator and maintenance training, built around your own plant.

Boiler operator training →

Sources

  • Central Pollution Control Board — guidelines for minimum stack height — Formulas for stack height from SO₂ and particulate emission rates, and minimum heights by boiler capacity.
  • Environment (Protection) Amendment Rules, 2023 — Revised boiler emission standards and stack height provisions.